Time-Lapse Corrosion Monitoring 3

image

Integrity Challenge

It is important to have a good cement bond in the annulus across corrosive intervals. External coating on the pipe will lessen the risk of corrosion. However, if the cement quality is poor and early corrosion is identified then it is essential to increase the frequency of corrosion logging to determine the integrity of the pipe and predict the rate of corrosion. This will allow remedial action to be planned in a timely manner to avoid catastrophic failure. This will also provide data to predict corrosion rates for similar wells.

Corrosion Logging Result

One example when corrosion monitoring was done in one well as shown below:

The well is a horizontal ESP oil producer drilled in 2013. The well was completed with a 9 5/8” uncoated surface casing, a 7” intermediate casing and a 4.5” production liner. A 3.5” ESP completion string was run in hole.

The first corrosion log was done in 2017, 4 years after the well was put on production. The EMDs log data indicated the presence of two corroded intervals at the shallow section of the well. Maximum metal loss across the upper interval was approximately 25%. In the lower interval the maximum metal loss was approximately 12%.

The second corrosion log was done in 2019. The EMDs log data showed that metal loss across the upper interval had increased to 35% whereas metal loss across the lower interval had increased to 20%.

The third corrosion log run was run in 2021. Maximum metal loss across the upper interval had increased to almost 60%, and across the lower interval increased to 30%. An additional interval with almost 40% metal loss was detected at 73 m which was not recorded in the 2017 and 2019 log data.

image

Based on the calculated metal loss from the 3 logging surveys, the corrosion trend for each interval was plotted as shown below. It can be seen that the corrosion rate is more aggressive in the middle interval. The very high annual rate of corrosion predicts that the metal loss will reach 100% in approximately 4-5 years. The corrosion rate across the upper interval is stabilizing at a few percent per year and will reach 100% in the next 10-15 years. Metal loss across the lower interval shows an increased rate of corrosion where metal loss will reach 100% in approximately 7 years. With more aggressive corrosion in the middle and lower intervals this can lead to a potential of corrosion migrating to the inner pipe. Regular logging of the well gives the client a better understanding of the overall well integrity and therefore can plan remedial action in advance. In this particular case the client planned to run a scab liner to mitigate any leak to surface.

image

All case studies

Looking for more information?

Get in touch with us and our representative will get back to you

Contact Us
>